Загрузить техническое описание
The Keysight N1070A combines the N4877A with the N1075A Optical Pick-Off/Converter to achieve optical clock recovery up to 32 Gb/s. The wide data rate range allows testing of emerging standards like 100GbE and 32GFC while covering existing standards.
The N1075A optical pick-off/converter which is part of the N1070A Optical Clock Data Recovery Solution is available in two versions. A dual single-mode/multimode version up to 14 Gb/s for a wide range of applications. A single-mode version up to 32 Gb/s offers enough headroom for forward error correction schemes of next generation network standards.
In combination with a Digital Communication Analyzer equipped with optical sampling heads like the 86116C and 86105C/D the very low intrinsic jitter paired with tunable loop bandwidth and selectable peaking enable accurate measurements of transceivers.
The settin gs of the solutions clock data recovery can be controlled through its rear-panel USB connection and a standalone user interface that runs on a Windows® PC. The SW can be installed on instruments running Windows XP or Windows 7.